| 1 | 3/11 14:46:00 | 0 | 0.00 | Earthquake | 
      
         | 2 | 3/11 14:47:35 | 95 | 0.03 | Reactor scram | 
      
         | 3 | 3/11 14:48:45 | 165 | 0.05 | MSIV closed | 
      
         | 4 | 3/11 15:05:00 | 1,140 | 0.32 | RCIC manually started | 
      
         | 5 | 3/11 15:25:00 | 2,340 | 0.65 | RCIC automatically tripped (L-8) | 
      
         | 6 | 3/11 15:36:00 | 3,000 | 0.83 | Tsunami hit | 
      
         | 7 | 3/11 15:38:00 | 3,120 | 0.87 | Station black-out | 
      
         | 8 | 3/11 16:03:00 | 4,620 | 1.28 | RCIC manually started | 
      
         | 9 | 3/12 11:36:00 | 75,000 | 20.83 | RCIC automatically tripped | 
      
         | 10 | 3/12 12:06:00 | 76,800 | 21.33 | Alternative S/C spray by DDFP | 
      
         | 11 | 3/12 12:35:00 | 78,540 | 21.82 | HPCI automatically started (L-2) | 
      
         | 12 | 3/13 02:42:00 | 129,360 | 35.93 | HPCI manually stopped | 
      
         | 13 | 3/13 03:05:00 | 130,740 | 36.32 | Alternative S/C spray by DDFP was stopped. Completion of switchover to alternative water injection into the reactor reported to MCR | 
      
         | 14 | 3/13 05:08:00 | 138,120 | 38.37 | Alternative S/C spray by DDFP started (switched over from the alternative water injection line into the reactor) | 
      
         | 15 | 3/13 07:39:00 | 147,180 | 40.88 | Alternative D/W spray by DDFP started (switched over from the alternative S/C spray) | 
      
         | 16 | 3/13 07:43:00 | 147,420 | 40.95 | Alternative S/C spray by DDFP was halted | 
      
         | 17 | 3/13 08:40:00 to 09:10:00 | 150,840 to 152,640 | 41.9 to 42.4 | Alternative D/W spray by DDFP halted. Switched over to alternative water injection line into the reactor. | 
      
         | 18 | around 3/13 09:08:00 | around 152,520 | around 42.37 | Reactor depressurized | 
      
         | 19 | 3/13 09:20:00 | 153,240 | 42.57 | PCV pressure decrease by venting confirmed | 
      
         | 20 | 3/13 09:25:00 | 153,540 | 42.65 | Freshwater injection started by fire engines | 
      
         | 21 | 3/13 11:17:00 | 160,260 | 44.52 | Closure of AO-valve of S/C venting line confirmed due to loss of driving gas pressure | 
      
         | 22 | 3/13 12:20:00 | 164,040 | 45.57 | Freshwater injection terminated due to water inventory depletion in fire protection pools. Switching over to seawater injection started | 
      
         | 23 | 3/13 12:30:00 | 164,640 | 45.73 | S/C vent valve opened for PCV venting | 
      
         | 24 | 3/13 13:12:00 | 167,160 | 46.43 | Seawater injection line configured and injection started | 
      
         | 25 | 3/14 01:10:00 | 210,240 | 58.40 | Water injection halted to make up the water source pit | 
      
         | 26 | 3/14 03:20:00 | 218,040 | 60.57 | Water source pit make up done. Seawater injection resumed | 
      
         | 27 | 3/14 05:20:00 | 225,240 | 62.57 | Small S/C vent valve (AO) opening started for PCV venting | 
      
         | 28 | 3/14 06:10:00 | 228,240 | 63.40 | Small S/C vent valve (AO) opening started for PCV venting | 
      
         | 29 | 3/14 11:01:00 | 245,700 | 68.25 | Unit 3 reactor building exploded | 
      
         | 30 | 3/14 11:01:00 | 245,700 | 68.25 | Seawater injection halted (as consequence of the explosion) | 
      
         | 31 | 3/14 15:30:00 | 261,840 | 72.73 | Seawater injection resumed | 
      
         | 32 | 3/14 19:30:00 to 19:54:00 | 276,240 to 277,680 | 76.73 to 77.13 | Seawater injection halted (fire engines found to have been out-of-service from 30 min to 1 hour before 19:20) | 
      
         | 33 | 3/14 21:14:00 | 282,480 | 78.47 | Seawater injection halted | 
      
         | 34 | 3/15 02:30:00 | 301,440 | 83.73 | Seawater injection resumed | 
      
         | 35 | 3/15 16:05:00 | 350,340 | 97.32 | S/C vent valve closure assumed for PCV venting |