The FP distributions inside the RPV, PCV, and R/B were evaluated using MAAP and SAMPSON codes. Table 1. shows the analysis results of distribution of Cs and Sr, which are the representative FP nuclide. The large uncertainties in the analysis results of both codes are caused by variations of FP models and chemical form of FP nuclide considering evaluation model.
Area | Unit 1 | Unit 2 | Unit 3 | |||
---|---|---|---|---|---|---|
Cs | Sr | Cs | Sr | Cs | Sr | |
Inside the RPV | 10ス90 | 0.4ス0.7 | 20ス150 | 13ス33 | 38ス110 | 11ス46 |
Inner wall of D/W | 6ス29 | 0.2ス0.3 | Approx. 0.9 | 0.2ス0.4 | less than 0.1- 1 | less than 0.1 |
S/P underwater | 26ス74 | 0.4ス2 | 27ス130 | 3ス4 | 57ス140 | 1ス6 |
Release to environment | less than 0.1-4 | less than 0.1 | less than 0.1-6 | less than 0.1-0.4 | less than 0.1-4 | less than 0.1 |